Every plated hole has at least three diameters: the pad diameter, the drill diameter and the finished hole diameter. CAD tools usually store one number. The fab has to handle all three. If the data does not say which diameter is meant and which one the tolerance applies to, the result is an engineering query (EQ), or boards where component leads and press-fit pins do not fit.
The three diameters
- Finished hole size: the usable diameter after plating and surface finish. Through-hole leads and press-fit pins mate with this size.
- Drill size: the diameter of the drill bit. A plated hole gets copper on the barrel wall after drilling, so the hole shrinks. The drill must be larger than the finished hole.
- Pad diameter: the outer diameter of the copper ring around the hole. Pad diameter minus drill size, divided by two, is the nominal annular ring.
Assembly fit depends on the finished size. Annular ring depends on the drill size. They refer to different diameters, and most hole problems start there.
How a fab converts finished size to drill size
Designers normally specify finished size. During CAM, the fab adds an allowance for barrel plating and surface finish to get the drill size, then picks the nearest drill bit. The allowance depends on the plating requirement and the finish type, so the same finished size can map to a different drill size under a different finish.
Two consequences follow:
- Do not add the allowance yourself. If the drill table already lists drill sizes without saying so, the fab adds the allowance a second time and the holes come out oversize. List finished sizes throughout and state "hole sizes are finished sizes" on the fabrication drawing.
- Calculate annular ring from the drill size. The drill is larger than the finished hole, so a ring calculated from finished size is optimistic.
SKPCB's standard minimum mechanical drill is 0.2 mm; 0.15 mm is an advanced capability that needs engineering review. Maximum aspect ratio for plated holes is 10:1. When small holes meet thick boards, check the aspect ratio first.
PTH, NPTH and press-fit holes: separate tolerances
The three hole types do different jobs and need separate tolerances:
| Hole type | Function | SKPCB hole tolerance |
|---|---|---|
| PTH (plated through-hole) | Interconnect, through-hole soldering | ±0.075 mm |
| NPTH (non-plated hole) | Mounting, location | ±0.05 mm |
| Press-fit hole | Mechanical and electrical contact for press-fit pins | ±0.05 mm |
Press-fit holes are held tighter than ordinary PTH because the pin relies on an interference fit. An oversize hole loses retention force; an undersize hole will not accept the pin or damages the barrel. List press-fit holes as their own tool in the drill table, never under the same size as ordinary PTH. Connector mounting as a whole is covered in PCB connector mounting and press-fit hole inputs.
If an NPTH has the same nominal size as a PTH, list it separately too. NPTH holes are not plated, so they get no allowance. Under a shared size the fab cannot tell them apart.
Annular ring budget: hole position eats the nominal ring
Nominal annular ring = (pad diameter − drill size) ÷ 2. That is the width when the hole lands exactly on the pad centre. In production, holes shift: SKPCB hole position accuracy is ±0.05 mm. When a hole shifts toward one side, the ring narrows on that side and widens on the other. The narrowest point decides whether the ring breaks out.
The budget must subtract at least three items:
- Plating allowance: work from the drill size, not the finished size.
- Hole position deviation: drill position relative to the pattern.
- Layer-to-layer registration (inner layers of multilayer boards): the offset between inner-layer pattern and drill after lamination. It grows with layer count, so inner-layer rings need more margin than outer-layer rings.
A pad sized only for the nominal ring can be close to zero at its narrowest point after these deductions. Agree the ring with the fab based on layer count and acceptance class (IPC-6012 Class 2 and Class 3 treat breakout differently) rather than releasing CAD defaults. Stackup and registration effects are covered on the multilayer PCB page.
Where drill tables and fab drawings usually conflict
- Drill table shows drill sizes, fab drawing shows finished sizes: the two files disagree and the fab has to raise an EQ.
- One blanket tolerance: a note such as "all holes ±0.1 mm" is too loose for press-fit pins and loosens NPTH as well.
- Press-fit holes not listed separately: they get treated as ordinary PTH, with ordinary tolerance and plating.
- Too many near-identical sizes: 0.30, 0.32 and 0.35 mm on one board means three drill bits. Merging sizes for holes with the same function reduces tool changes and mix-ups.
- Via treatment not stated: say whether vias are plugged and whether they may run at the low end of tolerance. Resin-filled via acceptance is covered in resin-filled via acceptance review.
Drill inputs to freeze before release
- Drill table lists finished sizes; the fabrication drawing states "hole sizes are finished sizes".
- PTH, NPTH and press-fit holes listed separately, each with its own tolerance; press-fit holes reference the pin part number or the pin maker's recommended hole.
- Surface finish decided (it affects the drill allowance).
- Acceptance class decided (IPC-6012 Class 2 / Class 3), which fixes the breakout requirement.
- Board thickness and smallest hole checked against aspect ratio.
- Via treatment (tented, open, plugged) stated.
For the full file set, see the Gerber file preparation checklist. SKPCB tolerances are listed on the manufacturing tolerance page. The plating process itself (desmear, electroless copper, electroplating) is covered in through-hole plating on double-sided PCBs.
Summary
A plated hole has a finished size, a drill size and a pad diameter. Assembly fit depends on the finished size; annular ring depends on the drill size. List finished sizes throughout, give each hole type its own tolerance, and budget the ring after plating allowance, hole position and registration. Freeze finish, acceptance class and via treatment before release so the fab can build straight from the data.
FAQ
Q: Should the drill table list finished hole size or drill size?
A: Finished size, stated on the fabrication drawing. The fab converts to drill size based on plating and finish; adding your own allowance risks having it added twice.
Q: What hole tolerances does SKPCB hold?
A: PTH ±0.075 mm, NPTH ±0.05 mm, press-fit ±0.05 mm. Hole position accuracy is ±0.05 mm.
Q: Why list press-fit holes separately?
A: Their tolerance is tighter than ordinary PTH because the pin relies on an interference fit. Under an ordinary PTH size they get ordinary tolerance.
Q: Which diameter is the annular ring based on?
A: The drill size, minus hole position deviation and, on multilayer boards, layer registration. The narrowest point decides breakout.
Q: Why can the same finished size map to different drill sizes?
A: The allowance depends on barrel plating and surface finish. A different finish can need a different allowance.
Q: What is the smallest hole SKPCB can drill?
A: 0.2 mm standard mechanical drill; 0.15 mm advanced with engineering review. Maximum plated-hole aspect ratio is 10:1.